SP001D-L Sensor Automatic Flush Valve Usage Manual
(Applicable for water tank of 1-pc toilet seat)

Thanks, Your Excellency, for choosing the series of SALUS? sensor automatic sanirtaryware.Using our products is your greatest trust and support for us.Our consistent service aim is  to offer you high-quality service whole-heartedly. To serve you better, ensuring that our product functions fine and to prolong its use life. We seriously advise you to read the product’s operation instruction manual in details before installation and usage.

I. Features
1.Automatic infrared X-ray induction: dual flushes –half flush and full flush.
2.The red light glitters and the valve starts to count time once there is a body in induction range: make no flush
when induction time is less than 10 seconds;make half flush when isinduction time is whihin 10-60 seconds;make
full flush when induction time is more than 60 seconds.The times fixed above are adjustable according to pratical need.
3.The water volume of half and full flushes is adjustable.And the speed of flush is high.The valve is applicable for all kinds of water tanks.
4.There is wireless connection between induction window and flush valve.And induction window can be placed neatly.
5.Sense window should be placed on the inner side of the cover of water tank.The valve cuts off power when the cover is closed to save power furthest.
6.Auto switch off fuction: The valve turns off water automatically when power off without any leakage to save water.
7.The valve saves power.No need to replace batteries within one to one-and-half years,while the valve is powered by high quality alkali batteries and there are 50 flushes per day.
8.Integrate with three functions to remove the re-take restrictions : induction,hand-handling and tool-handling functions.
II . Fuctions
1. Fuctions of Induction Window
Power-up Hint:the light glitters for once when power on;
Induction Hint:Indicator light glitters quickly continuously, while the induction is efficient.Make no flush after the user gets out of induction range,when induction time is less than 10 seconds;
When induction time is whihin 10-60 seconds,the indicator light glitters for once,and half flush works after the user’s being out of induction range for 2 seconds.
Induction Distance: Default standard state is 65±5cm( adjustable range:0-100cm );
Overtime Induction Hint:If induction time is over 2 hours,indicator light glitters every other two seconds to reveal overtime induction;
Lack Voltage Hint:If the voltage of batteries is too low,indicator light glitters for once every other second to reveal replacing batteries.The product will work normally after changing batteries.
2.Fuctions&Usage of Flush Valve
Power-up Hint:When power up,the buzzer makes a sound of “di1-“;
Low-Voltage Hint:When the voltage is too low,the buzzer makes two sounds of “di1-di1-” before each flush to reveal replacing baterries;
Lack Voltage Hint:When the power of batteries is near used up,the buzzer makes two sounds of “di1-di1-“every other two senconds to reveal replacing batteries;or the power of batteries will be used up;
Usage:A.The flush valve should adjust work code complying with induction window ,for its normal work under the control of induction window.
B.Water flush volume of half&full flushes are adjustable with eight levels.If flush effect isn’t satisfied, you B.Water flush volume of half&full flushes are adjustable with eight levels.
If flush effect isn’t satisfied, you can asjust water flush volume according to the relative content of induction window;
C.If something jams water outlet,the buzzer makes three sounds of “di1-di1-di1-“.Flush valve makes no flush untill the jam is solved.

For more Automatic Toilet Flusher,please contact us.
III. Technical Datas
Water Inlet Valve Induction Window Water Outlet Valve
Water Supply Press 0.02-0.8MPa —————— ——————
Water Inlet/Outlet G1/2” —————— Φ59
Flow Volume >6L/Min(0.1MPa) —————— 2.2L/S
Power Supply —————— DC4.5V(3 AA alkali batteries) DC4.5V(4 AA alkali batteries)
Induction Distance —————— 1-70cm ——————
Induction Time —————— 10-60S Half Flush
Over 60S Full Flush
IV. Installation
1.Assemblies of Products
感应窗正面Front of Induction Window 感应窗背面Back of Induction Window 排水阀 Flush Valve 排水阀底座Base of Flush Valve
2.Preparation before Installation: Please clean up the water tank&pipe before the installation of the product.
3. Diagram of Installation:
①Open package to unscrew flush valve and its base;
②③④Place U retaining ring into water outlet(Note: lay the base of water outlet valve flat),and tightly screw the screw of U retaining ring after adjust the place of flush valve.
⑤⑥⑦Unscrew the top cover of flush valve,and pull up seal cover of battery container to place 4 AA alkali batteries (note the anode and cathode),and then recover the aboves;
⑧⑨⑩Screw flush valve to its base,and plug fillng water tube into flush valve(Note:the height of filling water tube should beyond water level);
(11)(12)Tear off 3M mucilage protection film at the back of induction window,and smoothly place induction window in the center of the cover of toilet seat,with its sharp-point upturned.
(13)(14)(15)(16)Eddy induction window for 70°in anti-clock direction to pull up the cover of induction window,and then place batteres(note the anode and cathode).Indicator light glitters
for once to reveal the success of placing batteries.
Then adjust the cover of induction window to the direction of its being pulled up,and screw it to its previous place in clock-wise direction.That is all.

V. Manual Function
Press fuction key of induction window,then indicator light glitters;leave fuction key,then indicator light turns off.
(The time slot of two continuous key-presses should less than three seconds;if not,the key-press operation is ineffective.)
①One key-press:Enter into manual operation state of half flush.
②Two continuous key-presses:Enter into manual operation state of full flush.
③Three continuous key-presses:Enter into switching state of induction function & manual function.Tolerant state is induction
function state.(You can switch induction function and manual function circularly.);
④Four continuous key-presses:Enter into code adjustment state.Wait for about three seconds of indicator light’s glitters ,
after 4 continuous key-presses.When flush valve correctly receives signal of induction window, the buzzer makes a sound of “di1-“.(The flush valve have adjusted berore leaving factory,
and it needn’t to adjust work code under normal usage.);
⑤Five continuous key-presses:Enter into the fuction menu of half flush volume adjustment(eight levels totally,and the incremental change of each level is 0.5L flush volume);
Setting Way:A.Wait for no more than three seconds of three glitters after five key-presses;
B. Press function key when indicator light glitters,then indicator lights on;leave function key,then indicator light turns off. Repeat this operation for 1-8 times relatively for 1-8 level’s setting.
⑥Six continuous key-presses:Enter into the fuction menu of full flush volume adjustment(eight levels totally,and the incremental change of each level is 1.0L flush volume.)
Setting Way:A.Wait for no more than three seconds of three glitters after six key-presses;
B.Press function key when indicator light glitters,then indicator lights on;leave function key,then indicator light turns off. Repeat this operation for 1-8 times relatively for 1-8 level’s setting.

VI.Mechanical Function
拉绳Pull Wire
You can open the water tank and lightly pull the pull wire for water flush
while induction window&fuction key both are out of work.

VII. Adjustment of Induction Distance
感应距离调节处Part of adjusting induction time
Increasing induction distance in clock-wise direction.
Reducing distance in anti-clock direction.
Adjustment Range:0-100cm
Factory-set Distance:65±5cm

VIII. Diagram of Usage
0~100cm 自动冲水Auto Flush 自动关水Auto Turn Off

IX. Solution of Common Troubles
MALFUNCTION CAUSATION SOLUTION
Higher/lower water level. 1.Not correctly adjust inlet water level. 1.Adjust inlet water level.(Re. diagram)

1.Not open water inlet switch. 1. Open water inlet switch.
Water fails in going 2.Filter net jam because of bad water quality. 2.Clean filter net.
through water inlet 3.Not tightly screw inlet water valve screw. 3.Tightly screw inlet screw.(Re. diagram)
valve or leaks. 4.Something wrong with floating bucket of 4.Adjust the place of floating backet,
water inlet valve. and clear away any barrier.

Water leaks in flush 1.Not tightly screw the base of flush valve. 1.Tightly screw outlet screw.(Re. diagram)
valve. 2.Not correctly install flush valve. 2.Adjust the place of flush valve.(Re. diagram)
3Lackage of batteries voltage. 3.Place new alkali batteries.(Re. diagram)

Flush valve cannot flush. 1.Induction window donot correctly adjust code 1.Adjust work code.(Re. introduction manual)
comply with flush valve.
2.Induction distance is too far or too near. 2. Adjust induction distance.(Re. diagram)
3.Lackage of batteries voltage. 3.Place new alkali batteries.(Re. diagram)

Bad effect of flush. 1.Not correctly adjust water flush volume. 1.Adjust water flush volume.(Re. introduction manual)
1.Contrarily places induction window. 1.Adjust the place of induction window.(Re. diagram)
Induction window makes 2.Lackage of batteries voltage. 2.Place new alkali batteries.(Re. diagram)
no induction. 3.Induction distance is too far or too near. 3.Adjust induction distance.(Re. diagram)
X.Caution
1.Not install the product under the environment of sharp infrared evironment;
2.Should keep the induction window clean. And not clean induction window with organic liquor;
3.Not emphatically lay down the cover of toilet seat .Slow-falling cover is recommended;
4.Not clean fittings of water tank and induction window with caustic cleanser;
5.Not place caustic cleaning balls in water tank;
6.Not place any barrier in induction range to make the induction window under long-term induction situation;
7.Please use flush valve and induction window with the same bar code.Donnot optionally match them;
8.Not tightly screw the screw of water inlet valve;
9.Not use old batteries with new ones;
10.Should tightly screw the covers of battery container of flush valve & induction window, for water proof.
11.All rights of changing the product’s appearance and package and supplying the product are reserved.

 